{"id":29434,"date":"2025-08-12T16:32:05","date_gmt":"2025-08-12T20:32:05","guid":{"rendered":"https:\/\/avtech.com\/articles\/?p=29434"},"modified":"2025-08-12T16:33:04","modified_gmt":"2025-08-12T20:33:04","slug":"how-to-configure-bacnet-on-room-alert-max","status":"publish","type":"post","link":"https:\/\/avtech.com\/articles\/29434\/how-to-configure-bacnet-on-room-alert-max\/","title":{"rendered":"How To Configure BACnet On Room Alert MAX"},"content":{"rendered":"\n<p>You can configure your Room Alert MAX Base Station to communicate using BACnet, enabling seamless integration with your existing Building Management System (BMS) or Building Automation System (BAS).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Follow these instructions to configure BACnet on your Base Station:<\/h2>\n\n\n\n<ol>\n<li>First, open the Base Station\u2019s web interface.<br>You may do this by typing its IP address directly into your browser\u2019s URL.<br>For help, please see\u00a0<a href=\"https:\/\/avtech.com\/articles\/172\/\" target=\"_blank\" rel=\"noreferrer noopener\">How To Discover A Room Alert Monitor<\/a>\u00a0&amp;\u00a0<a href=\"https:\/\/avtech.com\/articles\/13255\/\" target=\"_blank\" rel=\"noreferrer noopener\">How To Open Your Room Alert Monitor\u2019s Built-in Web Interface<\/a>.<\/li>\n\n\n\n<li>Log In to the web interface.<br>For help, please see&nbsp;<a href=\"https:\/\/avtech.com\/articles\/166\/\" target=\"_blank\" rel=\"noreferrer noopener\">How To Access A Room Alert Monitor\u2019s Password-Protected Pages<\/a>.<\/li>\n\n\n\n<li>Navigate to\u00a0<strong>Settings<\/strong>\u00a0\u2192\u00a0<strong>BACnet<\/strong>.<br><img decoding=\"async\" loading=\"lazy\" width=\"1423\" height=\"1418\" class=\"wp-image-29435\" style=\"width: 500px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2025\/08\/BACnet_Settings.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2025\/08\/BACnet_Settings.png 1423w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2025\/08\/BACnet_Settings-300x300.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2025\/08\/BACnet_Settings-1024x1020.png 1024w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2025\/08\/BACnet_Settings-150x150.png 150w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2025\/08\/BACnet_Settings-768x765.png 768w\" sizes=\"(max-width: 1423px) 100vw, 1423px\" \/><\/li>\n\n\n\n<li>Check <strong>Enabled <\/strong>and fill-in the following <em>BACnet Device Settings<\/em>:\n<ul>\n<li>In <em>Device Instance<\/em>, enter a unique number to identify this device on the BACnet network.<\/li>\n\n\n\n<li>In <em>Network Number<\/em>, enter the BACnet network identifier assigned to this segment of your system.<\/li>\n\n\n\n<li>In <em>APDU Timeout<\/em>, you may keep the default value of 3000 milliseconds or enter a different value to adjust<br>the amount of time the device waits for an acknowledgment of a confirmed request.<\/li>\n\n\n\n<li>In <em>Number of Retries<\/em>, you may keep the default value of 3 or enter a different value to change how many times the device attempts to send a confirmed request if no acknowledgment is received.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>(Optional) In <em>Foreign Device Registration<\/em>, check <strong>Enabled <\/strong>to allow the device to communicate across subnets via your BACnet Broadcast Management Device (BBMD).\n<ul>\n<li>In <em>BBMD Address<\/em>, enter the IP address or hostname of your BBMD.<\/li>\n\n\n\n<li>In <em>BBMD UDP Port<\/em>, enter the UDP port number used by the BBMD device. The default is 47808, a commonly-used port.<\/li>\n\n\n\n<li>In <em>Registration Interval<\/em>, you may keep the default value of 300 seconds or enter a different value to adjust how often the device re-registers with your BBMD.<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Select <strong>Save <\/strong>at the bottom of the page.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>You can configure your Room Alert MAX Base Station to communicate using BACnet, enabling seamless integration with your existing Building Management System (BMS) or Building Automation System (BAS). Follow these instructions to configure BACnet on your Base Station:<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ngg_post_thumbnail":0},"categories":[2],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/avtech.com\/articles\/29434\/how-to-configure-bacnet-on-room-alert-max\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How To Configure BACnet On Room Alert MAX - AVTECH\" \/>\n<meta property=\"og:description\" content=\"You can configure your Room Alert MAX Base Station to communicate using BACnet, enabling seamless integration with your existing Building Management System (BMS) or Building Automation System (BAS). Follow these instructions to configure BACnet on your Base Station:\" \/>\n<meta property=\"og:url\" content=\"https:\/\/avtech.com\/articles\/29434\/how-to-configure-bacnet-on-room-alert-max\/\" \/>\n<meta property=\"og:site_name\" content=\"AVTECH\" \/>\n<meta property=\"article:published_time\" content=\"2025-08-12T20:32:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-12T20:33:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2025\/08\/BACnet_Settings.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:creator\" content=\"@AVTECHSoftware\" \/>\n<meta name=\"twitter:site\" content=\"@AVTECHSoftware\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Allie Wojtanowski\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"1 minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/avtech.com\/articles\/#website\",\"url\":\"https:\/\/avtech.com\/articles\/\",\"name\":\"AVTECH\",\"description\":\"Frequently Asked Questions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/avtech.com\/articles\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/avtech.com\/articles\/29434\/how-to-configure-bacnet-on-room-alert-max\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2025\/08\/BACnet_Settings.png\",\"width\":1423,\"height\":1418},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/avtech.com\/articles\/29434\/how-to-configure-bacnet-on-room-alert-max\/#webpage\",\"url\":\"https:\/\/avtech.com\/articles\/29434\/how-to-configure-bacnet-on-room-alert-max\/\",\"name\":\"How To Configure BACnet On Room Alert MAX - AVTECH\",\"isPartOf\":{\"@id\":\"https:\/\/avtech.com\/articles\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/avtech.com\/articles\/29434\/how-to-configure-bacnet-on-room-alert-max\/#primaryimage\"},\"datePublished\":\"2025-08-12T20:32:05+00:00\",\"dateModified\":\"2025-08-12T20:33:04+00:00\",\"author\":{\"@id\":\"https:\/\/avtech.com\/articles\/#\/schema\/person\/2966f1925021087dba64df344049f189\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/avtech.com\/articles\/29434\/how-to-configure-bacnet-on-room-alert-max\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/avtech.com\/articles\/#\/schema\/person\/2966f1925021087dba64df344049f189\",\"name\":\"Allie Wojtanowski\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/avtech.com\/articles\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/470c9c7fbbd3e0a96d84169645634d04?s=96&d=mm&r=g\",\"caption\":\"Allie Wojtanowski\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/29434"}],"collection":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/comments?post=29434"}],"version-history":[{"count":2,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/29434\/revisions"}],"predecessor-version":[{"id":29437,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/29434\/revisions\/29437"}],"wp:attachment":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/media?parent=29434"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/categories?post=29434"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/tags?post=29434"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}