{"id":21995,"date":"2024-11-30T16:45:52","date_gmt":"2024-11-30T21:45:52","guid":{"rendered":"https:\/\/avtech.com\/articles\/?p=21995"},"modified":"2025-01-08T08:19:47","modified_gmt":"2025-01-08T13:19:47","slug":"how-to-manage-security-settings-in-room-alert-manager","status":"publish","type":"post","link":"https:\/\/avtech.com\/articles\/21995\/how-to-manage-security-settings-in-room-alert-manager\/","title":{"rendered":"How To Manage Security Settings In Room Alert Manager"},"content":{"rendered":"\n<p>In Room Alert Manager, administrators can configure security settings, including:<\/p>\n\n\n\n<ul><li>maximum session times &amp; inactivity logouts<\/li><li>failed login limits &amp; lockout periods<\/li><li>password expirations<\/li><\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">To edit Room Alert Manager&#8217;s Security Settings, please follow the instructions below.<\/h4>\n\n\n\n<ol><li>Open Room Alert Manager in your web browser.<ul><li>You may open it by entering \u2018localhost:9393\u2019 or \u2018&lt;IP address of host system>:9393\u2019 in your browser\u2019s address bar. For more information, please see our FAQ,\u00a0<a href=\"https:\/\/avtech.com\/articles\/19834\/\" target=\"_blank\" rel=\"noreferrer noopener\">How to Open Room Alert Manager\u2019s Web Interface<\/a>.<\/li><\/ul><\/li><li>In order to configure Security Settings in Room Alert Manager, you must log in as an admin-level user.<ul><li>For more information, please see the \u201cTypes of user roles\u201d section of our FAQ,\u00a0<a href=\"https:\/\/avtech.com\/articles\/20112\/how-to-configure-users-in-room-alert-manager\/#types\" target=\"_blank\" rel=\"noreferrer noopener\">How To Configure Users In Room Alert Manager<\/a>.<\/li><\/ul><\/li><li>Navigate to <strong>Settings<\/strong> &#8211;> <strong>Security<\/strong>.<br><img decoding=\"async\" loading=\"lazy\" width=\"220\" height=\"498\" class=\"wp-image-25214\" style=\"width: 150px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/06\/RAM_Settings_Security-1.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/06\/RAM_Settings_Security-1.png 220w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/06\/RAM_Settings_Security-1-133x300.png 133w\" sizes=\"(max-width: 220px) 100vw, 220px\" \/><\/li><li>Show below are the <em>Security Settings<\/em> at defaults:<br><img decoding=\"async\" loading=\"lazy\" width=\"595\" height=\"859\" class=\"wp-image-22056\" style=\"width: 300px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/06\/RAM_DefaultSecuritySettings.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/06\/RAM_DefaultSecuritySettings.png 595w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/06\/RAM_DefaultSecuritySettings-208x300.png 208w\" sizes=\"(max-width: 595px) 100vw, 595px\" \/><\/li><\/ol>\n\n\n\n<ul><li>In <em>Max Session Time<\/em>, enter the maximum number of minutes that a user can be logged into a single Room Alert Manager session before their session expires, requiring them to log in again. <ul><li>The default is 1440 minutes (24 hours).<\/li><\/ul><\/li><li>In <em>Session Inactivity Limit<\/em>, enter the number of minutes that a user can be inactive before getting logged out of Room Alert Manager. <ul><li>The default is 30 minutes.<\/li><\/ul><\/li><li><em>Failed Login Limit<\/em> is disabled by default. <ul><li>Enable this feature if you&#8217;d like users to get locked out of Room Alert Manager for a period of time after too many failed login attempts.<\/li><\/ul><\/li><li>In <em>Max Failed Logins<\/em>, enter the number of consecutive failed login attempts that cause a user to get locked out of Room Alert Manager.<ul><li>The default (when this feature is enabled) is 5 attempts.<\/li><\/ul><\/li><li>In <em>Lockout Period<\/em>, enter the number of minutes that a user get locked out before they can attempt another login.<ul><li>The default (when this feature is enabled) is 30 minutes.<\/li><\/ul><ul><li>For information about unlocking a user, please see our FAQ, <a href=\"https:\/\/avtech.com\/articles\/21991\/\" target=\"_blank\" rel=\"noreferrer noopener\">How To Unlock Users In Room Alert Manager<\/a>.<\/li><\/ul><\/li><li><em>Password Expiration<\/em> is disabled by default.<ul><li>The default (when this feature is enabled) is 90 days.<\/li><\/ul><\/li><\/ul>\n\n\n\n<ol start=\"5\"><li>When you&#8217;re done making changes to your <em>Security Settings<\/em>, select <strong>Save Changes<\/strong>.<br><img decoding=\"async\" loading=\"lazy\" width=\"205\" height=\"66\" class=\"wp-image-21381\" style=\"width: 125px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/04\/RAM_SaveChanges.png\" alt=\"\"><\/li><\/ol>\n\n\n<div class=\"su-note\"  style=\"border-color:#bcc7cd;border-radius:5px;-moz-border-radius:5px;-webkit-border-radius:5px;\"><div class=\"su-note-inner su-u-clearfix su-u-trim\" style=\"background-color:#d6e1e7;border-color:#ffffff;color:#000612;border-radius:5px;-moz-border-radius:5px;-webkit-border-radius:5px;\">\n\n\n\n<p>To add an additional layer of security to user logins, please see our FAQ: <a href=\"https:\/\/avtech.com\/articles\/21967\/\" target=\"_blank\" rel=\"noreferrer noopener\">How To Use Multi-factor Authentication In Room Alert Manager<\/a>.<\/p>\n\n\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In Room Alert Manager, administrators can configure security settings, including: maximum session times &amp; inactivity logouts failed login limits &amp; lockout periods password expirations To edit Room Alert Manager&#8217;s Security Settings, please follow the instructions below. Open Room Alert Manager in your web browser. You may open it by entering \u2018localhost:9393\u2019 or \u2018&lt;IP address of [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ngg_post_thumbnail":0},"categories":[287],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/avtech.com\/articles\/21995\/how-to-manage-security-settings-in-room-alert-manager\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How To Manage Security Settings In Room Alert Manager - AVTECH\" \/>\n<meta property=\"og:description\" content=\"In Room Alert Manager, administrators can configure security settings, including: maximum session times &amp; inactivity logouts failed login limits &amp; lockout periods password expirations To edit Room Alert Manager&#8217;s Security Settings, please follow the instructions below. Open Room Alert Manager in your web browser. You may open it by entering \u2018localhost:9393\u2019 or \u2018&lt;IP address of [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/avtech.com\/articles\/21995\/how-to-manage-security-settings-in-room-alert-manager\/\" \/>\n<meta property=\"og:site_name\" content=\"AVTECH\" \/>\n<meta property=\"article:published_time\" content=\"2024-11-30T21:45:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-08T13:19:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/06\/RAM_Settings_Security-1.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:creator\" content=\"@AVTECHSoftware\" \/>\n<meta name=\"twitter:site\" content=\"@AVTECHSoftware\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Allie Wojtanowski\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"1 minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/avtech.com\/articles\/#website\",\"url\":\"https:\/\/avtech.com\/articles\/\",\"name\":\"AVTECH\",\"description\":\"Frequently Asked Questions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/avtech.com\/articles\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/avtech.com\/articles\/21995\/how-to-manage-security-settings-in-room-alert-manager\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/06\/RAM_Settings_Security-1.png\",\"width\":220,\"height\":498},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/avtech.com\/articles\/21995\/how-to-manage-security-settings-in-room-alert-manager\/#webpage\",\"url\":\"https:\/\/avtech.com\/articles\/21995\/how-to-manage-security-settings-in-room-alert-manager\/\",\"name\":\"How To Manage Security Settings In Room Alert Manager - AVTECH\",\"isPartOf\":{\"@id\":\"https:\/\/avtech.com\/articles\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/avtech.com\/articles\/21995\/how-to-manage-security-settings-in-room-alert-manager\/#primaryimage\"},\"datePublished\":\"2024-11-30T21:45:52+00:00\",\"dateModified\":\"2025-01-08T13:19:47+00:00\",\"author\":{\"@id\":\"https:\/\/avtech.com\/articles\/#\/schema\/person\/2966f1925021087dba64df344049f189\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/avtech.com\/articles\/21995\/how-to-manage-security-settings-in-room-alert-manager\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/avtech.com\/articles\/#\/schema\/person\/2966f1925021087dba64df344049f189\",\"name\":\"Allie Wojtanowski\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/avtech.com\/articles\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/470c9c7fbbd3e0a96d84169645634d04?s=96&d=mm&r=g\",\"caption\":\"Allie Wojtanowski\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/21995"}],"collection":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/comments?post=21995"}],"version-history":[{"count":13,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/21995\/revisions"}],"predecessor-version":[{"id":25215,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/21995\/revisions\/25215"}],"wp:attachment":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/media?parent=21995"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/categories?post=21995"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/tags?post=21995"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}