{"id":21219,"date":"2024-11-18T16:32:35","date_gmt":"2024-11-18T21:32:35","guid":{"rendered":"https:\/\/avtech.com\/articles\/?p=21219"},"modified":"2025-01-08T08:20:43","modified_gmt":"2025-01-08T13:20:43","slug":"how-to-configure-light-and-relay-actions-in-room-alert-manager","status":"publish","type":"post","link":"https:\/\/avtech.com\/articles\/21219\/how-to-configure-light-and-relay-actions-in-room-alert-manager\/","title":{"rendered":"How To Configure Light And Relay Actions In Room Alert Manager"},"content":{"rendered":"<div class=\"su-note\"  style=\"border-color:#bcc7cd;border-radius:5px;-moz-border-radius:5px;-webkit-border-radius:5px;\"><div class=\"su-note-inner su-u-clearfix su-u-trim\" style=\"background-color:#d6e1e7;border-color:#ffffff;color:#000612;border-radius:5px;-moz-border-radius:5px;-webkit-border-radius:5px;\">\n\n\n\n<p>In order to toggle a Light Tower or Relay action on your Room Alert &#8216;S&#8217; model, Room Alert Manager needs the device credentials. Please see our FAQ, <a href=\"https:\/\/avtech.com\/articles\/21705\/\" target=\"_blank\" rel=\"noreferrer noopener\">How To Save Device Credentials In Room Alert Manager<\/a>.<\/p>\n\n\n<\/div><\/div>\n\n\n\n<p><strong>Follow these instructions to configure your Light and Relay Action:<\/strong><\/p>\n\n\n\n<ol><li>Open Room Alert Manager in your web browser.<ul><li>You may open it by entering \u2018localhost:9393\u2019 or \u2018:9393\u2019 in your browser\u2019s address bar. For more information, please see our FAQ,&nbsp;<a rel=\"noreferrer noopener\" href=\"https:\/\/avtech.com\/articles\/19834\/\" target=\"_blank\">How to Open Room Alert Manager\u2019s Web Interface<\/a>.<\/li><\/ul><\/li><li>Navigate to&nbsp;<strong>Actions<\/strong> &#8211;&gt;<strong> Light\/Relay Profiles <\/strong>in the navigation bar to the left.<br><img decoding=\"async\" loading=\"lazy\" width=\"216\" height=\"332\" class=\"wp-image-22729\" style=\"width: 150px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_Actions_Menu_RelayLT.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_Actions_Menu_RelayLT.png 216w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_Actions_Menu_RelayLT-195x300.png 195w\" sizes=\"(max-width: 216px) 100vw, 216px\" \/><\/li><li>Then select <strong>Create a New Profile<\/strong>.<br><img decoding=\"async\" loading=\"lazy\" width=\"864\" height=\"242\" class=\"wp-image-22730\" style=\"width: 600px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/LightRelayConfigProfile.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/LightRelayConfigProfile.png 864w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/LightRelayConfigProfile-300x84.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/LightRelayConfigProfile-768x215.png 768w\" sizes=\"(max-width: 864px) 100vw, 864px\" \/><\/li><li>The <em>Light and Relay Action Form<\/em> will appear, where you may name your action and select the device that your light tower or relay is connected to.<br><img decoding=\"async\" loading=\"lazy\" width=\"959\" height=\"355\" class=\"wp-image-21229\" style=\"width: 600px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm.png 959w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm-300x111.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm-768x284.png 768w\" sizes=\"(max-width: 959px) 100vw, 959px\" \/><ul><li>In our example, we&#8217;ve named our action &#8220;Toggle DC light Tower &#8211; Critical.&#8221; In the <em>Select a device<\/em> drop-down menu, we&#8217;re choosing the Room Alert 32E in our Data Center.<br><img decoding=\"async\" loading=\"lazy\" width=\"958\" height=\"319\" class=\"wp-image-21232\" style=\"width: 600px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_Select-Device.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_Select-Device.png 958w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_Select-Device-300x100.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_Select-Device-768x256.png 768w\" sizes=\"(max-width: 958px) 100vw, 958px\" \/><\/li><\/ul><\/li><\/ol>\n\n\n<div class=\"su-note\"  style=\"border-color:#bcc7cd;border-radius:5px;-moz-border-radius:5px;-webkit-border-radius:5px;\"><div class=\"su-note-inner su-u-clearfix su-u-trim\" style=\"background-color:#d6e1e7;border-color:#ffffff;color:#000612;border-radius:5px;-moz-border-radius:5px;-webkit-border-radius:5px;\">\n\n\n\n<p>Only one Room Alert Monitor is allowed per each <em>Light and Relay Action<\/em>. If you wish to toggle multiple Room Alert Monitors, you must create a separate <em>Light and Relay Action<\/em> for each. You may then associate multiple actions with your alert.<\/p>\n\n\n<\/div><\/div>\n\n\n\n<ol start=\"5\"><li>Once you select a device, you&#8217;ll see any internal or external relays or light towers connected to that device.<ul><li>In our example, our Room Alert 32E has 1 external light tower (named &#8220;DC Light Tower&#8221;), 1 external relay (named &#8220;DC Relay&#8221;), and 2 internal relays.<br><img decoding=\"async\" loading=\"lazy\" width=\"957\" height=\"1494\" class=\"wp-image-21233\" style=\"width: 600px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_FullDefaults.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_FullDefaults.png 957w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_FullDefaults-192x300.png 192w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_FullDefaults-656x1024.png 656w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_FullDefaults-768x1199.png 768w\" sizes=\"(max-width: 957px) 100vw, 957px\" \/><\/li><\/ul><\/li><li>You may configure alert &amp; clear behaviors for any or all of the device&#8217;s light tower and relays.<ul><li>In our example, we are only configuring settings for the device&#8217;s external Light Tower:<br><img decoding=\"async\" loading=\"lazy\" width=\"953\" height=\"490\" class=\"wp-image-21235\" style=\"width: 600px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_DCLightTower.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_DCLightTower.png 953w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_DCLightTower-300x154.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_LightRelayActionForm_DCLightTower-768x395.png 768w\" sizes=\"(max-width: 953px) 100vw, 953px\" \/><\/li><li>When our action is executed <em>On Alert<\/em>, the red LED &amp; Audio 1 will turn on. When our action is executed <em>On Clear<\/em>, the red LED and Audio 1 will turn off, and the green LED will turn on.<\/li><li>Any elements in our list with the drop-down option set to &#8220;None&#8221; will not get toggled on or off by this action.<\/li><\/ul><\/li><\/ol>\n\n\n<div class=\"su-note\"  style=\"border-color:#bcc7cd;border-radius:5px;-moz-border-radius:5px;-webkit-border-radius:5px;\"><div class=\"su-note-inner su-u-clearfix su-u-trim\" style=\"background-color:#d6e1e7;border-color:#ffffff;color:#000612;border-radius:5px;-moz-border-radius:5px;-webkit-border-radius:5px;\">\n\n\n\n<p>Light tower LEDs\/audio and relay toggles that are set to &#8220;None&#8221; in Room Alert Manager can still be toggled elsewhere. You may have settings in your device&#8217;s local web interface, in our legacy Device ManageR software, or in a third-party SNMP program that toggles these elements.<\/p>\n\n\n<\/div><\/div>\n\n\n\n<ol start=\"7\"><li>Select <strong>Save Changes<\/strong> to save your action.<br><img decoding=\"async\" loading=\"lazy\" width=\"177\" height=\"59\" class=\"wp-image-21243\" style=\"width: 120px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/SaveChanges.png\" alt=\"\"><\/li><li>You\u2019ll return to the main <em>Actions<\/em> list, where you can view your action details.<br><img decoding=\"async\" loading=\"lazy\" width=\"955\" height=\"588\" class=\"wp-image-21244\" style=\"width: 600px;\" src=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_Actions_List.png\" alt=\"\" srcset=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_Actions_List.png 955w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_Actions_List-300x185.png 300w, https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_Actions_List-768x473.png 768w\" sizes=\"(max-width: 955px) 100vw, 955px\" \/><\/li><li>Once your action is configured, you may associate it with any alert. Please see our FAQ,&nbsp;<a href=\"https:\/\/avtech.com\/articles\/20409\/\" target=\"_blank\" rel=\"noreferrer noopener\">How To Create Alerts In Room Alert Manager<\/a>.<\/li><\/ol>\n\n\n<div class=\"su-note\"  style=\"border-color:#bcc7cd;border-radius:5px;-moz-border-radius:5px;-webkit-border-radius:5px;\"><div class=\"su-note-inner su-u-clearfix su-u-trim\" style=\"background-color:#d6e1e7;border-color:#ffffff;color:#000612;border-radius:5px;-moz-border-radius:5px;-webkit-border-radius:5px;\">\n\n\n\n<p>Working with a Room Alert 12E purchased in 2021? Please see our FAQ, <a href=\"https:\/\/avtech.com\/articles\/22357\/\" target=\"_blank\" rel=\"noreferrer noopener\">Why Your Room Alert 12E Built-in Relay Behavior May Be Reversed<\/a>.<\/p>\n\n\n<\/div><\/div>\n\n\n","protected":false},"excerpt":{"rendered":"<p>Follow these instructions to configure your Light and Relay Action: Open Room Alert Manager in your web browser. You may open it by entering \u2018localhost:9393\u2019 or \u2018:9393\u2019 in your browser\u2019s address bar. For more information, please see our FAQ,&nbsp;How to Open Room Alert Manager\u2019s Web Interface. Navigate to&nbsp;Actions &#8211;&gt; Light\/Relay Profiles in the navigation bar [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"ngg_post_thumbnail":0},"categories":[287],"tags":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/avtech.com\/articles\/21219\/how-to-configure-light-and-relay-actions-in-room-alert-manager\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How To Configure Light And Relay Actions In Room Alert Manager - AVTECH\" \/>\n<meta property=\"og:description\" content=\"Follow these instructions to configure your Light and Relay Action: Open Room Alert Manager in your web browser. You may open it by entering \u2018localhost:9393\u2019 or \u2018:9393\u2019 in your browser\u2019s address bar. For more information, please see our FAQ,&nbsp;How to Open Room Alert Manager\u2019s Web Interface. Navigate to&nbsp;Actions &#8211;&gt; Light\/Relay Profiles in the navigation bar [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/avtech.com\/articles\/21219\/how-to-configure-light-and-relay-actions-in-room-alert-manager\/\" \/>\n<meta property=\"og:site_name\" content=\"AVTECH\" \/>\n<meta property=\"article:published_time\" content=\"2024-11-18T21:32:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-08T13:20:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_Actions_Menu_RelayLT.png\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:creator\" content=\"@AVTECHSoftware\" \/>\n<meta name=\"twitter:site\" content=\"@AVTECHSoftware\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Allie Wojtanowski\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/avtech.com\/articles\/#website\",\"url\":\"https:\/\/avtech.com\/articles\/\",\"name\":\"AVTECH\",\"description\":\"Frequently Asked Questions\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/avtech.com\/articles\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/avtech.com\/articles\/21219\/how-to-configure-light-and-relay-actions-in-room-alert-manager\/#primaryimage\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/avtech.com\/articles\/wp-content\/uploads\/2021\/03\/RAM_Actions_Menu_RelayLT.png\",\"width\":216,\"height\":332},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/avtech.com\/articles\/21219\/how-to-configure-light-and-relay-actions-in-room-alert-manager\/#webpage\",\"url\":\"https:\/\/avtech.com\/articles\/21219\/how-to-configure-light-and-relay-actions-in-room-alert-manager\/\",\"name\":\"How To Configure Light And Relay Actions In Room Alert Manager - AVTECH\",\"isPartOf\":{\"@id\":\"https:\/\/avtech.com\/articles\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/avtech.com\/articles\/21219\/how-to-configure-light-and-relay-actions-in-room-alert-manager\/#primaryimage\"},\"datePublished\":\"2024-11-18T21:32:35+00:00\",\"dateModified\":\"2025-01-08T13:20:43+00:00\",\"author\":{\"@id\":\"https:\/\/avtech.com\/articles\/#\/schema\/person\/2966f1925021087dba64df344049f189\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/avtech.com\/articles\/21219\/how-to-configure-light-and-relay-actions-in-room-alert-manager\/\"]}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/avtech.com\/articles\/#\/schema\/person\/2966f1925021087dba64df344049f189\",\"name\":\"Allie Wojtanowski\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/avtech.com\/articles\/#personlogo\",\"inLanguage\":\"en-US\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/470c9c7fbbd3e0a96d84169645634d04?s=96&d=mm&r=g\",\"caption\":\"Allie Wojtanowski\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/21219"}],"collection":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/comments?post=21219"}],"version-history":[{"count":25,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/21219\/revisions"}],"predecessor-version":[{"id":25106,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/posts\/21219\/revisions\/25106"}],"wp:attachment":[{"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/media?parent=21219"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/categories?post=21219"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/avtech.com\/articles\/wp-json\/wp\/v2\/tags?post=21219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}